Fplp Plenum Fire Alarm Cable
Fplp Plenum Fire Alarm Cable. There are many uses for fire alarm cable such as smoke alarms, smoke detectors, and other protection systems. Wesbell fplp shielded fire alarm cable is a limited plenum cable.

This is the type of cable used to connect various Ethernet networks. There are four pairs of wires inside the cable. There is a thick plastic separator to keep each pair completely isolated throughout the run of cable. Both pairs is connected by a twist, which means there is in no way to interfere with devices that are connected to the network. The wires are also bent at various intervals, so they are not causing interference between themselves. If you are in an area where there's a significant amount Electromagnetic Interference (EMI), like mechanical spaces or a mechanical space, it's possible the shielded version of the twisted pair with an outer shielding layer that offers extra protection from EMI. Category 5e, 6, 6A and 7 are common selections today. Twisted pair cable can be used up to 295' for horizontal runs. Twisted couple cable is used in a variety of applications. Standard station cabling for computers and VOIP phones wireless access devices, network cameras, access control along with building and construction maintenance are but several. It is among the most reliable kinds of cables. When they are in use, network failures are much less frequent than when other cables are utilized.
Fiber optic cables are primarily used as a backbone cable however it is becoming used more and more as a station cable (think"FIOS"). By "backbone" cable, I mean it connects Telecommunication Rooms within an area to one another. Fiber optic cable comes with huge bandwidth capacities that permit it to carry massive amounts of data at super-fast speeds. Fiber optic cables can reach great distances(hundreds of meters) in comparison to copper cables. Because they must be so efficient and the information can travel such distances there are numerous layers of protective coatings that are present on their fiber optic cables. Fiber cables transmit light as rather than electrical current. Fiber optic cables consume less energy than high-speed copper does. Fiber optic cable is a good choice for high-speed reliable communications.
The cable paths should stay free of electrical light fixtures as well as different sources for EMI (Electro Magnetic Interference). Keep cable routes in accessible places on the ceiling to allow for future cable runs as well as ease of maintenance. All paths should be laid over corridors, hallways, or hallways. cables are introduced into individual rooms by sweeping 90 degree turns. Install a firestop sleeve or putty in all areas of an fire wall. Be cautious when pulling cables, so as not to make them bend beyond their bend radius. This could result into a failure when conducting tests. Do not tie cables to suspended ceilings or pipes for sprinklers. They should be tied at five feet at a minimum on horizontal runs and more often on vertical runs. J-hooks should be attached to the deck below. Wrap velcro around them every 5' or so , when you've completed running cable to provide your cable bundles with a great looking finish.
Our cables are ul, etl listed and rohs compliant. The plenum rating refers to the material used in the jacket of the cable. Unshielded plenum fire alarm cable fplp, 16 awg 4.
Skip To The Beginning Of The Images Gallery.
Skip to the end of the images gallery. The armor is not an equipment grounding means. Our cables are ul, etl listed and rohs compliant.
Rated For Use From 0°C To +75°C.
The plenum rating refers to the material used in the jacket of the cable. The plenum (fplp) fire alarm cable has two 16 gauge solid bare copper conductors. Unshielded plenum fire alarm cable fplp, 16 awg 4.
Sequential Footage Markings On The Jacket Help Facilitate The Installation Process, As You Always Know How Much Cable Is Remaining.
Wesbell fplp shielded fire alarm cable is a limited plenum cable. Wiring of fire alarms, smoke detectors, voice communications, burglar alarms, fire protective circuits. Superior emi shielding versus aluminum armor.
Call Us For Best Shipping Option!
It can also be used for smoke detectors and voice. 3) fplp which is a power limited plenum cable and they are recognized by the nec for use in air ducts and plenum spaces and any other. This product may be available in one of our regional warehouses.
Fire Alarm Circuit Integrity, Emergency Systems, And Healthcare Facilities (Nec Articles 760, 700 & 517).
Fire alarm cable plenum (fplp) application: Fplp plenum, fire alarm cable, unshielded, 500ft or 1000ft spool. Fire alarm/control cable is a traditional type mc cable containing one or more copper grounding conductors;